HPLC Archives - Purtek Instruments Limited https://www.puretekinstruments.com/products/hplc/ Professional Gas chromatograph, HPLC, spectrohotometer and chromatographic consumables manufacturer in China Fri, 25 Mar 2022 07:09:50 +0000 en-US hourly 1 https://wordpress.org/?v=7.1.3 HPLC column https://www.puretekinstruments.com/product/hplc-column/ Fri, 04 Mar 2022 02:52:51 +0000 https://www.puretekinstruments.com/?post_type=avada_portfolio&p=151 Supersil® series columns are upgraded from Hypersil series according to years of experience in technical accumulation and inheritance. The development makes them more outstanding with higher separation efficiency, longer service life and smaller batch difference. NO. Item Specifications USP code 1 Supersil ODS2 3 µm 120 Å L1 2 Supersil ODS2 5 µm 120 Å [...]

The post HPLC column appeared first on Purtek Instruments Limited.

]]>

Supersil® series columns are upgraded from Hypersil series according to years of experience in technical accumulation and inheritance. The development makes them more outstanding with higher separation efficiency, longer service life and smaller batch difference.

NO.

Item

Specifications

USP code

1

Supersil ODS2

3 µm 120 Å

L1

2

Supersil ODS2

5 µm 120 Å

L1

3

Supersil AQ-C18

5 µm 120 Å

L1

4

Supersil ODS-B

5 µm 120 Å

L1

5

Supersil SiO2

5 µm 120 Å

L3

6

Supersil C8

5 µm 120 Å

L7

7

Supersil NH2

5 µm 120 Å

L8

8

Supersil NH2-S

5 µm 120 Å

L8

9

Supersil SCX

5 µm 120 Å

L9

10

Supersil SCX

5 µm 300 Å

L9

11

Supersil CN

5 µm 120 Å

L10

12

Supersil Phenyl

5 µm 120 Å

L11

13

Supersil C4

5 µm 120 Å

L26

14

Supersil C4

5 µm 300 Å

L26

The post HPLC column appeared first on Purtek Instruments Limited.

]]>
HPLC column oven https://www.puretekinstruments.com/product/hplc-column-oven/ Fri, 04 Mar 2022 02:50:50 +0000 https://www.puretekinstruments.com/?post_type=avada_portfolio&p=149 PT-D2000 HPLC COLUMN OVEN Temperature: room temp. +5℃ ~100℃ Constant temp. tolerance: ±0.1℃ Temperature repeatability: ±0.1℃ Absolute precision: ±0.1℃ at 50℃ Resolution: 0.1℃ Double-row LED screen to indicate setting temp. and actual temp. Can install 2 LC column(250mm*4.6mm) No need software to control

The post HPLC column oven appeared first on Purtek Instruments Limited.

]]>

PT-D2000 HPLC COLUMN OVEN

Temperature: room temp. +5℃ ~100℃

Constant temp. tolerance: ±0.1℃

Temperature repeatability: ±0.1℃

Absolute precision: ±0.1℃ at 50℃

Resolution: 0.1℃

Double-row LED screen to indicate setting temp. and actual temp.

Can install 2 LC column(250mm*4.6mm)

No need software to control

The post HPLC column oven appeared first on Purtek Instruments Limited.

]]>
HPLC PT-LC3100 https://www.puretekinstruments.com/product/hplc-pt-lc3100/ Fri, 04 Mar 2022 02:47:50 +0000 https://www.puretekinstruments.com/?post_type=avada_portfolio&p=147 HPLC PT-LC3100 High Pressure Constant Flow Pump for Isocratic and Binary gradient  Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) Flow precision: RSD≤0.075% (1.00ml/min, H2O,R.T.,8.5MPa) Maximum pressure: 45 MPa Pressure accuracy: ≤±3.0% Pressure pulsation: ≤0.1 MPa Low-Pressure Gradient Unit for Quaternary Integrated vacuum degasser, 4 channel Composition rang: [...]

The post HPLC PT-LC3100 appeared first on Purtek Instruments Limited.

]]>

HPLC PT-LC3100

  1. High Pressure Constant Flow Pump for Isocratic and Binary gradient 
  • Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments
  • Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
  • Flow precision: RSD≤0.075% (1.00ml/min, H2O,R.T.,8.5MPa)
  • Maximum pressure: 45 MPa
  • Pressure accuracy: ≤±3.0%
  • Pressure pulsation: ≤0.1 MPa

Low-Pressure Gradient Unit for Quaternary

  • Integrated vacuum degasser, 4 channel
  • Composition rang: 0-100%
  • Composition precision: ≤0.2% RSD
  • Composition accuracy: ≤±2.0% 
  1. UV detector
  • Wavelength range: 190-700 nm
  • Wavelength repeatability: ≤0.1 nm
  • Wavelength accuracy: ≤±1.0 nm
  • Bandwidth: 8nm
  • Response time: 0.0 s-5 s
  • Baseline noise: ≤±0.5×10-5 AU
  • Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
  • Path length: 10 mm(analytical cell)
  • Light source: Deuterium Lamp 
  1. Refractive Index Detector
  • Flow cell type:2 chamber-type
  • Measuring method:Deflection type
  • Refractive Index range:00 to 1.75
  • Measuring range:25 to 512μRIU
  • Drift:2μRIU/h (Pure water 1mL/min, PURGE OFF)
  • Linearity range:≥600μRIU
  • Noise:≤2.5nRIU (Pure water, response : 1.5sec)
  • Response:1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec
  • Cell volume:8μL
  • Flow rate:(Usual) 0.2 to 3.0mL/min;(Max.) 10mL/min (solvent: pure water)
  1. Evaporative Light Scattering Detector
  • Light source: high intensity halogen lamp
  • Detector: high sensitivity photomultiplier
  • Analogue signal output: 0-1V
  • Heating time:<10min heat-up to 150℃
  • Temperature range: evaporation chamber max 150℃, increase by 1℃, nebulizer max 70℃
  • Gas flow rate: 1-2L/min, recommended pressure 1-2bars
  • Noise<1m Volt(1ml/min)
  • Nebulizer type: venture tube 
  1. Diode Array Detector
  • 512 diodes
  • Wavelength range: 190-760 nm
  • Wavelength repeatability: ±0.1 nm
  • Wavelength accuracy: ±1nm
  • Baseline noise: ≤±1.0×10-5 AU (empty cell, 254 nm, 1.0 s)
  • Drift: ≤2.0×10-4 AU/h (empty cell, 254 nm, 60 min)
  • Path length: 10 mm (analytical cell)
  • Light source: Deuterium Lamp and Tungsten Lamp 
  1. Fluorescence Detector
  • Light source: Xenon flash lamp
  • Wavelength Range: 0, 200 nm to 650 nm (Dual wavelength simultaneous monitoring possible)
  • Spectral Bandwidth: 20 nm
  • Wavelength Accuracy: ±2 nm
  • Wavelength Reproducibility: ±0.2 nm
  • S/N: Water Raman peak S/N 1200 min
  • Cell (capacity, pressure resistance, material): 12 µL; 2 MPa (approx. 20 kgf/cm2); SUS316L, PTFE (fluororesin), quartz
  1. Autosampler
  • Inject volumn range: 0-100 μL (standard)
  • Precision: RSD <0.3%
  • linearity: >0.999
  • Sample residual: <0.01%
  • Number of sample plates: Two of 60 position 2-mL vial plates
  • Syringe: 500 μL
  1. Column oven
  • Column capacity: Three columns, up to 10mm internal diameter, up to
  • 250mm length with guard column
  • Temperature range: room temperature+5.0 to 80℃, settable in 0.1℃ increments
  • Temperature accuracy: ≤±0.5℃
  • Temperature stability: ≤±0.1℃ 

Optional column oven(cooling function)

  • Column capacity: 3 columns up to 300mm length
  • Cooling function temperature range: 5 to 80℃
  • Normal temperature range: room temperature to 100℃
  • Accuracy: 0.1℃
  • Displayer: 4-digit LED
  1. Workstation
  • Internal and external standard calculation methods
  • Automatically displays, prints, exports and starts other programs after the completion of a measurement.
  • Comply with the requirements of the 21 CFR Part 11 directive of the FDA 
  1. On-line degasser
  • Maximum number of degassing Channel: 4
  • Flow path ID: 1.143mm
  • Internal volume: 480μL
  • Wetted Materials: PEEK, Teflon® AF

The post HPLC PT-LC3100 appeared first on Purtek Instruments Limited.

]]>
HPLC PT-LC1100 https://www.puretekinstruments.com/product/hplc-pt-lc1100/ Fri, 04 Mar 2022 02:47:13 +0000 https://www.puretekinstruments.com/?post_type=avada_portfolio&p=145 PT-LC1100 Isocratic/binary gradient High Pressure Constant Flow Pump  Double plunger reciprocating pump  Flow Range:0.001mL/min-10.000mL/min; Setting Step Size:0.001mL/min  Flow Accuracy:≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa)  Flow stability:RSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa)  Maximum Pressure:42MPa  Display Pressure Error:≤±3.0% Pressure Fluctuation:≤1.0%  Power Dissipation:80W  External Dimension (Length x Width x High):420mm×260mm×160mm UV/VIS Detector Wavelength Range:190-700nm Wavelength Repeatability:±0.1nm Wavelength Accuracy:≤±1.0nm Spectrum Band Width:8nm Response [...]

The post HPLC PT-LC1100 appeared first on Purtek Instruments Limited.

]]>

PT-LC1100 Isocratic/binary gradient

High Pressure Constant Flow Pump

  •  Double plunger reciprocating pump
  •  Flow Range:0.001mL/min-10.000mL/min;
  • Setting Step Size:0.001mL/min
  •  Flow Accuracy:≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa)
  •  Flow stability:RSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa)
  •  Maximum Pressure:42MPa
  •  Display Pressure Error:≤±3.0%
  • Pressure Fluctuation:≤1.0%
  •  Power Dissipation:80W
  •  External Dimension
  • (Length x Width x High):420mm×260mm×160mm

UV/VIS Detector

  • Wavelength Range:190-700nm
  • Wavelength Repeatability:±0.1nm
  • Wavelength Accuracy:≤±1.0nm
  • Spectrum Band Width:8nm
  • Response Time:0.0s-4.9s
  • Linearity Range:1.8AU (5%)
  • Baseline Noise:≤±1×10-5AU
  • Baseline Drife:≤2.0×10-4AU/h
  • minimum Detectable Concentration:4.0×10-9g/mL (Naphthalene in Methanol Solution)
  • Detector Cell:Optical Path–10mm,Volume–10μL
  • Light Source:Deuterium Lamp
  • Power Dissipation:100W
  • External Dimension
  • (Length x Width x High):420mm×260mm×160mm

The post HPLC PT-LC1100 appeared first on Purtek Instruments Limited.

]]>